APCUPSD SERIAL DRIVER DOWNLOAD

It is, however, recommended that you first try contacting APC Technical Support to verify the correct battery constant value. Minutes of runtime to leave in battery UPS shuts down "early". This can be very helpful for checking the condition of your UPS and to know whether or not apcupsd is properly connected to it. It will read your installed apcupsd. The most likely cause of problems are:.
Uploader: Nikokasa
Date Added: 24 February 2018
File Size: 43.83 Mb
Operating Systems: Windows NT/2000/XP/2003/2003/7/8/10 MacOS 10/X
Downloads: 62936
Price: Free* [*Free Regsitration Required]





APCUPSD User Manual

The ' make install ' must be run as root. That is, you install a single copy of apcupsd but launch it multiple times using different configuration wpcupsd and scripts.

There are four possible settings: This version of apcupsd sefial been built to run natively on Windows no Cygwin or other emulation layer needed. This program monitors multiple UPSes at the same time.

Called for an emergency system shutdown.

APCUPSD User Manual

This is the most common connection for modern UPSes, especially those used with Windows computers. If everything is set up correctly, it will print a bunch of HTML with the values of the machines that you have put in the hosts.

If you are performing an upgrade it will of course not replace your current config apcupsv. After the decision to replace the batteries, you will face another decision almost immediately: To test apcupsd, I unplugged the UPS to simulate a power outage.

This imposes a few minor restrictions on the functionality of some of the cables. You will configure each of these apcupsd's to use the 'net' driver to read UPS status from the proper instance of apcupsd on the UPS server.

Similarly, if the total runtime for a particular UPS is 30 minutes with a low battery signal warning time set at 10 minutes, then the UPS will run on battery for 20 minutes before the low battery alert begins.

The net result, is that in those situations hiddev is completely unusable so apcupsd will not work.

How to set up apcupsd with USB/RS-232 adapter

This is the simplest way to install. As far as I can tell, the only useful types are disable and always since the difference in the time when the logout warning is given and shutdown occurs for the other types is very short KES. This event is generated when the mains power returns after a powerout condition. Post as a guest Name. This event is generated when the mains return only if the onbattery event has been generated.

Most likely you will be left with an unusable system. You do so by editing the registry and changing the line:.

The Windows version of apcupsd is distributed as a simple double-click installer. No other arguments should be required, apcupwd your setup and platform should be detected automatically by configure. In principle, you should be able to do this with apcupssd computer powered by the UPS, but if you wish to be completely safe, you should plug your computer into the wall prior to performing the runtime calibration.

It's fundamentally stupid and self-defeating, but it's the kind of stupid that tends to sound good at an executive meeting. I'd recommend testing your USB-to-serial adapter separately from apcupsd using a terminal program and another PC with a null modem cable or equivalent means.

Generally, UPSes have a shutdown grace period which gives sufficient time for the OS to shutdown before the power is cut. This manual is divided into parts which increase in technical depth as they go. Item 2 will perform a Battery Runtime Calibration.

apcupsd | A daemon for controlling APC UPSes

Problem USB driver linux-usb. On my system, the UPS is configured as at the factory to have a second grace period before shutting off the power. The following command line options are available for configure to customize your installation. SmartUPS models only support bits 6 and 7. To start apcupsd manually as you will probably do immediately following the installationenter the following:.

Comments

Popular Posts